JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Adequate inventory
Bulk Purchase Discounts
Sold: 167392
Sold: 9823
Sold: 7921
Sold: 5329
Sold: 4376
Brand name:Shinko
Model number:JCM-33A.A-M1C5
Price:Inquiry for discount
Packaging:Wooden Box / Carton
Delivery time:7~14 days (About)
Warranty:1 Year
Parameter details:Contact support to obtain
Payment methods:Consulting support, including your preferred payment methods.
Quick Quote
Input For the input type, refer to the "Rated scale". Thermocouple: External resistnace, 100Ω or less RTD: 3-wire system(Resistance per wire: 10Ω or less) DC current: Input impedance, 50 Ω shunt resister between input terminals) DC voltage: Input impedance, 1M Ω or greater(for input 0 to 1 V DC) Input impedance, 100k Ω or greater(for inputs 0 to 10 VDC, 1 to 5V DC, 0 to 5V DC) Accuracy(setting, indication) Thermocouple: Within ± 0.2% of each input span ±1 digit, or within ±2℃(4℉),whichever is greater However, R.S inputs, 0 to 300℃(600℉): Accuracy is not guaranteed. K,J,E,T,N inputs, less than 0℃(32℉): Within 0.4% of each input span ±1 digit. Input samping period 0.25 seconds Control output Relay contact: 1a1b 3A 250V AC(resistive load), 1A 250VAC(inductive load cos= 0.4) Non-contact voltage: 12 DC Max. 40mA(short-circuit protection) Control action PID, PI, PD,ON/OFF Alarm 1(A1) Alarm action and Engerized/Deenergized can be selected by the keypad operation No alarm action High limit alarm(deviation setting). Low limit alarm(deviation setting), High limit alarm with standby(deviation setting).Low speed alarm with standby(devision setting) Setting range:——(Input span) to input span High/low limits alarm (deviation setting), High/Low limit range alarm(deviation setting),High/Low limits alarm with standby(deviation setting) setting range 0 to input span Process high alarm, Prossess low alarm Setting range: Input range low limit value to input range high limit value Whrn input has a decimal point, the nagative minimum vaule is - 199.9 and the positive maximum vaule is 999.9 For DC current or voltage inputs, input span is the same as input range scaling low limit(high limit) vaule is the same as input range scaling low limit(limit) vaule. Action: ON/OFF action Output Relay contact 1a: 3A 250V AC(resistive load). 1A 250V AC(inductive load) Supply voltage 100 to 240V AC 50/60Hz, 24V AC/DC 50/60Hz Allowable voltage fluctuation range: 85 to 264V AC, 20 to 28V Power consumption Appreox. 8VA Ambient temperature 0 to 50℃ Ambient humidity 35 to 85% RH(Non-condensing) Mounting method Screw type mounting bracket Mounting panel thickness: Within 1 to 15mm Attached function Sensor correction, Setting value lock, Power failure countermeasure, Self-diagnosis, Automatic cold juncition temperature compensation(for thermocouple only), Sensor burnout alarm, Input burnout Option Refer to the "Model name".
Enjoy 10% off shipping on orders of 50+ pieces, or 20% off on orders of 200+ pieces.Estimated Delivery: 1-2 weeks (subject to actual situation).
After-Sales guaranteeReturns and exchanges within 30 days require the item to be unused, undamaged, and in its original packaging.
Shopping safety24/7 Online SupportSecure PaymentProtected LogisticsPrivacy Guarantee
Factory AddressPengzhou, Chengdu, Sichuan, ChinaPhnom Penh, CambodiaNaypyidaw, Myanmar