JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Adequate inventory
Bulk Purchase Discounts
Sold: 167392
Sold: 9823
Sold: 7921
Sold: 5329
Sold: 4376
Brand name:Shinko
Model number:JCM-33A.S-M1A2
Product Condition:Factory New / New Surplus
Packaging:Wooden Box / Carton
Delivery time:7~14 days (About)
Warranty:1 Year
Parameter details:Contact support to obtain
Payment methods:Consulting support, including your preferred payment methods.
Quick Quote
Input For the input type, refer to the "Rated scale". Thermocouple: External resistnace, 100Ω or less RTD: 3-wire system(Resistance per wire: 10Ω or less) DC current: Input impedance, 50 Ω shunt resister between input terminals) DC voltage: Input impedance, 1M Ω or greater(for input 0 to 1 V DC) Input impedance, 100k Ω or greater(for inputs 0 to 10 VDC, 1 to 5V DC, 0 to 5V DC) Accuracy(setting, indication) Thermocouple: Within ± 0.2% of each input span ±1 digit, or within ±2℃(4℉),whichever is greater However, R.S inputs, 0 to 300℃(600℉): Accuracy is not guaranteed. K,J,E,T,N inputs, less than 0℃(32℉): Within 0.4% of each input span ±1 digit. Input samping period 0.25 seconds Control output Relay contact: 1a1b 3A 250V AC(resistive load), 1A 250VAC(inductive load cos= 0.4) Non-contact voltage: 12 DC Max. 40mA(short-circuit protection) Control action PID, PI, PD,ON/OFF Alarm 1(A1) Alarm action and Engerized/Deenergized can be selected by the keypad operation No alarm action High limit alarm(deviation setting). Low limit alarm(deviation setting), High limit alarm with standby(deviation setting).Low speed alarm with standby(devision setting) Setting range:——(Input span) to input span High/low limits alarm (deviation setting), High/Low limit range alarm(deviation setting),High/Low limits alarm with standby(deviation setting) setting range 0 to input span Process high alarm, Prossess low alarm Setting range: Input range low limit value to input range high limit value Whrn input has a decimal point, the nagative minimum vaule is - 199.9 and the positive maximum vaule is 999.9 For DC current or voltage inputs, input span is the same as input range scaling low limit(high limit) vaule is the same as input range scaling low limit(limit) vaule. Action: ON/OFF action Output Relay contact 1a: 3A 250V AC(resistive load). 1A 250V AC(inductive load) Supply voltage 100 to 240V AC 50/60Hz, 24V AC/DC 50/60Hz Allowable voltage fluctuation range: 85 to 264V AC, 20 to 28V Power consumption Appreox. 8VA Ambient temperature 0 to 50℃ Ambient humidity 35 to 85% RH(Non-condensing) Mounting method Screw type mounting bracket Mounting panel thickness: Within 1 to 15mm Attached function Sensor correction, Setting value lock, Power failure countermeasure, Self-diagnosis, Automatic cold juncition temperature compensation(for thermocouple only), Sensor burnout alarm, Input burnout Option Refer to the "Model name".
Inventory Availability:Please confirm the compressor is in stock and verify its core specifications before purchasing. We prioritize matching you with inventory from your local distributor, We provide actual photos for your confirmation before packaging and shipping.
Expedited Ordering:Please select the expedited option at checkout. For lightweight items, you can request "overnight or 2-day shipping". Our customer service will then confirm the expedited schedule (including preparation and shipping), with most orders delivered globally within 2-5 days.
Certification and Testing:Please ensure that you are purchasing a genuine product, which includes original manufacturer certification and professional test reports.
After-Sales and Support:Unless caused by human error, we promise free replacement or full refund. We provide a total of 3 years of warranty coverage, comprising a 1-year original manufacturer's warranty and an additional 2-year(In-House Warranty) extended warranty for repairs and support.
Repair Kit:We offer a repair kit that includes essential installation parts prone to wear and tear. For details, please contact our customer service.
Payment and Order Processing:We support a variety of mainstream payment methods (e.g., Visa, PayPal, TT). Our checkout process is quick and secure, with orders processed within the same day.
Bulk Orders:If you require a single, high-volume delivery, please inquire about our bulk order or wholesale pricing. We can then coordinate a delivery schedule and shipping time.
*Tips: 1. Before shipping, we will send you photos of the actual product for your confirmation ( eg. nameplate, appearance, and report). 2. The product comes with a 1-year manufacturer warranty policy and 3-year in-house warranty. 3. If the product is damaged during transportation or cannot be repaired due to non-human-caused within 1 year, no return, we will directly refund or resend the new product. 4. For select items, we will include a repair kit ( Special Needs Customer Service ). 5. Enjoy a worry-free experience throughout the entire process. Feel free to request quotes and place orders with confidence, we will provide 5-star service until you are satisfied. 6. Shipping and Taxes: See Quotation.
A: The choice depends on capacity and application. We recommend: Screw for large, stable loads and high efficiency; Reciprocating for smaller capacity or specialized low-temperature use; and Centrifugal for very high-capacity HVAC/chiller applications. We offer a data-driven sizing analysis.
A: Our systems are designed with industry-standard interfaces and utilize high-quality, globally recognized components. We ensure that critical accessories and spare parts are readily available through our own supply chain and cross-reference to minimize emergency lead times.
A: We perform a comprehensive heat load analysis that considers ambient temperature, product load, air infiltration, insulation U-values, and processing time. We use this data to select a compressor with the optimal capacity and EER/COP (Energy Efficiency Ratio/Coefficient of Performance) for your target temperature.
A: We provide a comprehensive warranty package (typically $12$-$24$ months on the compressor). We maintain a global inventory of critical spares and commit to an emergency parts lead time (e.g., $24$-$72$ hours to major industrial hubs) to ensure minimal operational disruption.
A: We provide a detailed TCO breakdown encompassing purchase, installation, maintenance, and projected energy costs. We prioritize Variable Speed Drive (VSD) compressors and advanced control systems to modulate capacity, minimizing energy consumption during part-load operation and maximizing long-term savings.
A: Absolutely. Our primary strength lies in supply capability. Whether it's OEM manufacturing or global inventory searches—from components to complete units—we can match your needs with the nearest partner's inventory for rapid delivery. Our global alliance enables transactions at wholesale agency rates. Welcome aboard! Cheers!!